Wynn’s Radiator FlushWynn's PowerFlush Cooling System Flush and Fill Machine have been designed to provide the following benefits:
- Provides the best means for a factory recommended cooling system service.
- Flushes contaminated fluid from the entire cooling system including the radiator, engine block, heater core and hoses.
- Eliminates cross-contamination of engine coolants.
- Performs a complete cooling system service in 20 minutes or less.
- Avoids coolant spillage by easy and quick connection to cooling system through the upper radiator hose.
- Completely portable and operates on 12V DC power.
- Pressure checks the cooling system.
Packaging325 ml
|
Wynn's Radiator Flush is a radiator cleaner, formulated to take maximum advantage of the best features of the cooling system, and is both easy and safe to use.
When used as directed, it will promote cooling system efficiency and better engine performance.
Introduction
Cooling system failure is the leading cause of mechanical breakdown on the highway.
Rust, corrosion, scale build-up, chemical breakdown and the formation of acids, all contribute to the likelihood of cooling system failure. If the cooling system fails, the engine and/or transmission could suffer sever damage, leading to costly repairs.
As a vehicle ages, the likelihood of cooling system failure increases. A conventional drain and fill will do little to address these problems as a large quantity of the old coolant
is left behind. In addition, the deposits and corrosion debris left behind will seriously impair the proper functions of the system.
Automobile manufacturers require scheduled engine coolant changes in order to maintain warranty coverage. Following the warranty period, engine coolant changes are still recommended on a specific schedule to maintain optimum condition of the cooling system.
Engine blocks, heater cores, hoses and water pumps are not typically drained during a traditional cooling system fluid drain and fill. In fact, up to 60% of the used contaminated fluid can remain in the system.
Just like motor oil and transmission fluid, engine coolant deteriorates over time, forming damaging scale and deposits.
Contaminants are difficult to remove when much of the old fluid remains in the cooling system. Much of this damaging debris stays in the cooling system, slowly deteriorating internal components.
Engine coolant drain and fill services can be messy, with a high likelihood of spillage of potentially hazardous waste onto the shop floor, and additional hazard in the workplace.
The use of Wynn's Radiator Flush with the Wynn's PowerFlush Cooling System Flush and Fill Machine is the solution to overcoming the above problems.
REMOVES RUST, GREASE, SLUDGE AND SCALE
While the damaging effects of rust in cooling systems is generally recognized, the harmful effects of grease and sludge are often overlooked. Sludge-forming oil enters the cooling system through leaky head gaskets and the use of inferior quality soluble oil type corrosion inhibitors which rapidly break apart. This type of cooling system contamination results in sludge accumulation in the radiator and reduced coolant flow unless removed by regular flushing.
Water contains dissolved inorganic matter which is present in the composition of soil and rock materials, which the water comes into contact with.
Because of its origin, water contains different amounts and types of scale forming solids, such as calcium, magnesium and silica.
Scale acts as an insulator and reduces the amount of heat that has to be transferred away into the cooling system.
For example, 0.75mm of scale has the same insulating properties of 5cm of steel.
Scale formation is of particular concern in large cooling systems where scale build-up traps heat and eventually causes engine problems.
NO NEUTRALISER NEEDED
Strong acid or strong alkali type radiator cleaners not only clean "too clean" to the extent of re-opening small holes that have been sealed over by rust and/or scale, but also continue to attack cooling system components until stopped by a neutralizing agent despite thorough flushing of the system with water. Wynn's Radiator Flush contains no harsh acid or alkali compounds and can be used safely without any neutralizing steps being required.
HARMLESS TO ALUMINIUM
Wynn's Radiator Flush is not only safe for the usual cast iron engine blocks and component parts but also for aluminum engine blocks. It has been particularly inhibited to make it harmless to aluminum alloys and other special alloys employed in cooling systems.
HARMLESS TO RADIATOR HOSES OR GASKETS
Because it is a specifically formulated radiator cleaner, Wynn's Radiator Flush will remove rust, scale, sludge, grease and other foreign materials from automotive cooling systems without damage to hoses, gaskets, metals or other cooling system components.
Wynn's Premium Radiator Flush has been formulated to provide the following benefits:
- Cleans radiators quickly and safely.
- Removes rust, sludge and scale deposits.
- Restores coolant flow and heat transfer efficiency.
- Safe with aluminum and other metal components.
- Compatible with cooling system components, hoses and gaskets.
Wynn's PowerFlush Cooling System Flush and Fill Machine have been designed to provide the following benefits:
- Provides the best means for a factory recommended cooling system service.
- Flushes contaminated fluid from the entire cooling system including the radiator, engine block, heater core and hoses.
- Eliminates cross-contamination of engine coolants.
- Performs a complete cooling system service in 20 minutes or less.
- Avoids coolant spillage by easy and quick connection to cooling system through the upper radiator hose.
- Completely portable and operates on 12V DC power.
- Pressure checks the cooling system.
Wynn's Radiator Flush safely removes rust, grease and sludge from the entire cooling system without damage to any part.
Follow vehicle manufacturer's recommended flushing procedures.
With engine off, remove coolant from overflow tank using the Wynn's Rapid Evacuation Tool. Release the pressure in the cooling system using the Wynn's Rapid Evacuation Tool. Remove radiator cap. Pinch centre of upper radiator hose with pinch pliers.
Remove coolant from radiator to a level below the upper radiator hose using the Wynn's Rapid Evacuation Tool. Remove hose from radiator and connect the appropriate male and female upper radiator hose adaptors. Securely fasten all fittings.
FeaturesWynn's PowerFlush Cooling System Flush and Fill Machine have been designed to provide the following benefits:
- Provides the best means for a factory recommended cooling system service.
- Flushes contaminated fluid from the entire cooling system including the radiator, engine block, heater core and hoses.
- Eliminates cross-contamination of engine coolants.
- Performs a complete cooling system service in 20 minutes or less.
- Avoids coolant spillage by easy and quick connection to cooling system through the upper radiator hose.
- Completely portable and operates on 12V DC power.
- Pressure checks the cooling system.
|
Materials Safety Data Sheet
RADIATOR FLUSH
|
|
Wynn's Australia Pty Ltd.
An (ITW), Illinois Tool Works Company .ABN 73 000 370 150
100 Hassall Street, Wetherill Park N.S.W. 2164
Private Bag 35, Wetherill Park DC N.S.W. 2164
|
TELEPHONE NUMBER:
(02) 9828 0900
|
|
PRODUCT IDENTIFICATION
Product Name | Wynn's Radiator Flush |
Other Names | 65310 325 ml |
Recommended Use | Water-based cleaner for engine cooling systems |
Supplier Name | Wynn's Australia Pty Ltd An (ITW), Illinois Tool Works Company ABN 73 000 370 150 |
Address | 100 Hassall Street, Wetherill Park N.S.W. 2164 Private Bag 35, Wetherill Park DC N.S.W. 2164 |
Telephone Number | (02) 9828 0900
Email : wynnsaus@wynns.net
Website : www.wynns.net |
Emergency Phone Number | (02) 9828 0900 Monday-Friday 8.00am - 5.00pm
13 11 26 (24 hours Australia) Poisons Information Centre (PIC)
0800 764 766 (New Zealand) Poisons Information Centre (PIC) |
HAZARDS IDENTIFICATION
Hazard Classification |
NON-HAZARDOUS SUBSTANCE. NON-DANGEROUS GOODS.
Not classified as hazardous according to the criteria of NOHSC.
Not classified as Dangerous Goods according to the criteria of the
ADG Code. |
Risk Phrase |
None |
Safety Phrase |
None |
COMPOSITION/INFORMATION ON INGREDIENTS
Pure substances : Not applicable - Mixture
Mixture
Chemical Identity |
CAS Number |
Proportion |
Water |
7732-18-5 |
< 1% |
Sodium Borate |
1303-96-4 |
< 1% |
Sodium Molybdate |
7631-95-0 |
< 1% |
Other non-hazardous ingredients |
- |
< 1% |
FIRST AID MEASURES
Ingestion |
Do NOT induce vomiting. Give water and call a doctor immediately. |
Skin |
Wash affected area with soap and water. Remove contaminated
clothing. |
Eye |
Flush with water for 15 minutes. If irritation persists, call for
medical help. |
Inhalation |
Remove person to fresh air to avoid further inhalation. |
First Aid Facilities |
Eye wash station. |
Advice to Doctor |
Treatment should be based on symptoms and clinical condition. |
FIRE FIGHTING MEASURES
Suitable Extinguishing Media |
Water, water spray, dry chemicals, foam. |
Hazards From Combustion Products |
Thermal decomposition may produce oxides of carbon and
sodium. |
Precautions For Fire Fighters |
Use water to cool fire exposed containers. |
Special Protective Equipment |
Fire fighters to wear a self contained breathing apparatus. |
Hazchem Code |
None allocated. |
ACCIDENTAL RELEASE MEASURES
Emergency Procedures |
Prevent product from entering drink water supplies and sewer. |
Methods and Materials
for Containment and
Clean Up Procedures |
Use absorbent, sand or clay. Shovel into containers. Remove to
outside. Prevent liquid from entering sewers and water ways.
Dispose of in accordance with Federal, State and Local regulations. |
HANDLING AND STORAGE
Precautions for Safe Handling |
Avoid skin and eye contact. Keep out of reach of children. |
Conditions for Safe Storage |
Avoid freezing. Do not store opened unenclosed bottles. Use entire contents.
|
EXPOSURE CONTROLS/PERSONAL PROTECTION
National Exposure Standards |
Name |
ES-TWA |
ES-STEL |
ES-Peak |
None established for product |
- |
- |
- |
|
None established for ingredients |
- |
- |
- |
|
Alternative Standards |
Contains no other ingredients now known to be hazardous as
defined by OSHA 29CFR 1910.1000(z) and 29CFR 1910.1200.
|
Biological Limit Values |
No biological limit allocated. |
Engineering Controls |
Normal ventilation |
Personal Protective Equipment |
Respiratory Protection |
None required |
Eye / Face Protection |
Safety glasses. |
Skin Protection |
Rubber, plastic gloves. |
Thermal Hazards |
None applicable. |
PHYSICAL AND CHEMICAL PROPERTIES
Appearance |
Clear thin green liquid |
Odour |
None |
pH Value |
8.5 (100% concentration) 8.3 (3% concentration in distilled water) |
Vapour Pressure |
Irrelevant |
Vapour Density |
Irrelevant |
Boiling Point/Range |
100°C |
Freezing Point |
0ÂșC |
Melting Point |
Not applicable |
Solubility |
100% in water |
Density |
1.050 @ 15°C |
Flash Point |
None |
Flammable Limits |
Not applicable |
Ignition Temperature |
Not applicable |
STABILITY AND REACTIVITY
Chemical Stability |
Stable |
Conditions to Avoid |
None applicable. Not flammable or combustible. |
Incompatible Materials |
Strong acids, oxidising materials. |
Hazardous Decomposition Products |
Thermal decomposition may produce oxides of carbon and sodium. |
Hazardous Reactions |
Polymerization will not occur. |
TOXICOLOGICAL INFORMATION
Toxicology Information
This material has not been identified as a carcinogen by NTP,
IARC or OSHA.
Acute Health Effects
Ingestion
May cause irritation to the digestive tract.
Inhalation
No effect.
Eye
May cause slight irritation, watery eyes and blurred vision.
Skin
May absorb on prolonged and repeated exposure. May cause
slight irritation on prolonged contact.
Chronic Health Effects
ECOLOGICAL INFORMATION
Ecotoxicity No ecotoxicological classifications.
Persistence/ Degradability Not available.
Mobility Miscible with water.
DISPOSAL CONSIDERATIONS
Disposal Methods
Ensure waste disposal conforms to local waste disposal regulations.
Avoid unauthorised discharge to sewer
Special Precautions for Landfill or Incineration
Material suitable for disposal by landfill through an approved agent.
TRANSPORT INFORMATION
UN Number Non regulated.
Proper Shipping Name Non regulated.
Class and Subsidiary Non regulated.
Risk.
Packing Group Non regulated.
Special Precautions
for User Non regulated. .
Hazchem Code Non regulated.
REGULATORY INFORMATION
Poisons Schedule None scheduled.
Hazard Category None scheduled.
OTHER INFORMATION
Acronyms
ABN Australian Business Number
ACGIH American Conference of Governmental Industrial Hygienists
ADG Australian Dangerous Goods
AICS Australian Inventory of Chemical Substances
AS Australian Standard
CAS Chemical Abstracts Service (USA)
COC Cleveland Open Cup
EPA Environment Protection Agency (Australian States)
IARC International Agency for Research on Cancer
IP Institute of Petroleum (UK)
NIOSH National Institute for Occupational Safety and Health (USA)
NOHSC National Occupational Health and Safety Commission
(Australia)
NTP National Toxicology Program (USA)
NZS New Zealand Standard
OSHA Occupational Safety and Health Administration (USA)
PEL Permissible Exposure Level
PMCC Pensky - Martens Closed Cup
SCBA Self-Contained Breathing Apparatus
STEL Short Term Exposure Limit
SUSDP Standard for the Uniform Scheduling of Drugs and Poisons
(Australia)
TLV Threshold Limit Valve
TWA Time Weighted Average
UN United Nations
Abbreviations
cP centiPoise
cSt centiStoke
g gram
Hg Mercury
kPa kiloPascal
L litre
m3 cubic metre
mg milligram
mL millilitre
mm millimetre
°C degrees of temperature in Celsius (Centigrade)
% percent(age)
Note
This form has been prepared in accordance with the National Code of
Practice for the Preparation of Material Safety Data Sheets 2nd Edition
[NOHSC:2011 (2003)] issued by the National Occupation Health and
Safety Commission April 2003.
All information contained in this form is as accurate as possible at the
time of issue. The data contained herein is not to be taken as an
expressed or implied warranty or representation, for which Wynn's
Australia Pty Ltd assumes legal responsibility. No responsibility for
damages resulting from use of the information are given, other than
those implied mandatorily by Federal or State Government
Legislation.
|
|
|
|