Wynns Power Charge

Formulated to:
  • Improve horsepower, fuel economy and Drive-ability by providing a cleaner fuel system.
  • Contain state of the art polyether amine deposit control additive technology.
  • Contain a patented combustion catalyst to increase power and reduce emissions.
  • Remove deposits on injectors, intake valves and in combustion chambers in the first tank-full.
  • Reduce a vehicle's demand for octane by up to 3 numbers.
  • Eliminate "rotten egg" odors.
  • Reduce particulate emissions in diesels.

Packaging


16 oz. bottles

Wynns Power Charge

Wynn's Power Charge contains unique patented technology, combining advanced engine power boosters with effective fuel system detergents and dispersants. Using Wynn's patented technology, Wynn's Power Charge is formulated to increase power and improve fuel economy while lowering tailpipe emissions. Wynn's Power Charge will also eliminate hesitation and knocking by removing fuel deposit buildup.

For the gas tank:

  • Provides corrosion protection.
  • Eliminates problems from water-contaminated fuel.

THE PROBLEM

Today's automobiles are marvels of modern science and engineering. They deliver more power and torque than cars of yesteryear, sometimes with half of the engine displacement. They do this while producing significantly lower emissions and providing longer life. Needless to say, these cars operate within very narrow windows of ignition timing, air/fuel ratio and other parameters. Small disruptions, such as those caused by fuel system deposits, can result in progressive and sometimes severe problems. These can include power loss, a reduction in mileage; drive-ability upset, and increased emissions.

Professional mechanics serve a clientele of frustrated motorists under more and more regulatory pressure to maintain their cars and keep engines running smoothly and within increasingly tighter legal emissions requirements. If the professional mechanic can satisfy these customers and save them costly repairs, he creates a trusting, loyal customer who will come back again and again. Below is an example of intake valve deposits that can disrupt fuel flow, leading to decreased drive-ability and fuel economy, and increased emissions.

THE SOLUTION

Wynn's Power Charge Fuel Treatment contains Wynn's unique patented technology, combining advanced engine power boosters with effective fuel system detergents and dispersants. Using Wynn's patented technology, Power Charge Fuel Treatment is formulated to increase power and improve fuel economy while lowering tailpipe emissions. Power Charge will also eliminate hesitation and knocking by removing fuel deposit buildup. When added as directed to the fuel tank of a new or used vehicle, the driver notices the immediate benefit of increased power and fuel economy.
Power Charge Fuel Treatment works in the fuel system as a catalyst to aid the effective combustion of fuel. It also cleans injectors, intake valves and combustion chambers of harmful, power robbing deposits. Wynn's Power Charge Fuel Treatment is formulated to treat 10 to 20 gallons of gasoline or diesel fuel. Use Power Charge Fuel Treatment every 3000 to 4000 miles or with every oil change to keep your customers' vehicles free from fuel system and combustion chamber deposits. Below is an example of a clean intake valve, allowing maximum drive-ability and fuel economy with minimum emissions.

Features

Formulated to:
  • Improve horsepower, fuel economy and Drive-ability by providing a cleaner fuel system.
  • Contain state of the art polyether amine deposit control additive technology.
  • Contain a patented combustion catalyst to increase power and reduce emissions.
  • Remove deposits on injectors, intake valves and in combustion chambers in the first tank-full.
  • Reduce a vehicle's demand for octane by up to 3 numbers.
  • Eliminate "rotten egg" odors.
  • Reduce particulate emissions in diesels.

Materials Safety Data Sheet

Wynn's Professional Products Power Charge
WYNN'S
A division of Illinois Tool Works Inc.
1151 West Fifth Street
Azusa, California 91702
EMERGENCY TELEPHONE NUMBER:
Chemtrec (800) 424-9300
INFORMATION TELEPHONE NUMBER:
Wynn's (626) 334-0231

PRODUCT IDENTIFICATION

PRODUCT NAMEEFFECTIVE DATEPRODUCT CODE
Wynn's Professional Products Power Charge® Fuel Treatment 3-9-06 66201, 66202
CHEMICAL NAMECAS NUMBER
N/AN/A



HAZARDOUS INGREDIENTS

COMMON NAMECHEMICAL NAMECAS NO.%OSHA PELACGIH TLV-TWA
Aromatic Solvent Light aromatic solvent naphtha 64742-95-6 Not Established Not Established
Petroleum Hydrocarbon Hydrotreated light distillates 64742-88-7 Not Established Not Established
DTBP Di-tert-butyl Peroxide 110-05-4 Not Established Not Established

Contains no other ingredients now known to be hazardous as defined by OSHA 29CFR 1910.1000(z) and 29CFR 1910.1200.




PHYSICAL DATA

These data are approximate or typical values and should not be used as precise specifications. Unless otherwise noted values are at 20°C(68°F) and 760 mmHg (1 atm).

Boiling Point/Range 230-530°F (110-277°C) Freeze Point N/D
Specific Gravity (H20=1) @ 15.6°C 0.84 Vapor Pressure (mm Hg) > 1
Vapor Density (Air =1) >1 Solubility in Water (%) 0-10% emulsible
% Volatiles by Volume N/D Evaporation Rate (Butyl Acetate = 1) >1
pH (as is) N/D pH (dilute) @ % N/A
Appearance Clear straw color liquid Odor Petroleum solvent odor
N/D - Not Determined
< = Less Than

N/A - Not Applicable
> = Greater Than



FIRE AND EXPLOSION HAZARD DATA

Flash Point 112°F(44°C) Method Pensky - Martens Closed Cup ASTM D-93

Hazard Class Identification
Flammability 2
Health 2
Reactivity 0
Other -
Hazard Code 0 - Least (insignificant)
1 - Slight
2 - Moderate
3 - High
4 - Extreme
Extinguishing Media
Dry chemicals, carbon dioxide, foam, water fog.

Special Fire Fighting Procedures
Do not enter fire area without proper protection including breathing apparatus. Stay at safe distance. Use water spray to cool fire exposed containers.

Unusual Fire and Explosion Hazards
Combustion may produce smoke, toxic fumes.


REACTIVITY DATA

Stability
Stable.

Conditions to Avoid
Sources of ignition such as heat, flames, sparks, etc.

Materials to Avoid
Acids, strong oxidizing agents such as nitrates.

Hazardous Decomposition or Combustion Products
Thermal decomposition may produce carbon dioxide, carbon monoxide and oxides of nitrogen.

Hazardous Polymerization (conditions) Polymerization will not occur.


HEALTH HAZARDS/ROUTES OF ENTRY

Signs, Symptoms and Effects of Overexposure
Ingestion (swallowing) May be harmful or fatal if swallowed. Due to its low viscosity, it may enter lungs during swallowing or vomiting. Once in lungs serious damage may occur.
Skin Contact Can cause skin irritation, defatting of skin, redness.
Eye Contact Eye irritant.
Inhalation (breathing) May irritate nose, throat, and lungs. Prolonged or repeated exposure to vapor may cause headache, dizziness, nausea, weakness and loss of coordination.
Other Effects of Prolonged/Repeated Overexposure
This material has not been identified as a carcinogen by NTP, IARC or OSHA. Above effects may be aggravated with repeated overexposure.


EMERGENCY AND FIRST AID PROCEDURES

Ingestion (swallowing) DO NOT induce vomiting. Call physician immediately
Skin Contact Remove all contaminated clothing. Wash thoroughly with soap and water. If signs of irritation develop, seek medical attention.
Eye Contact Remove any contact lens. Flush with clean water for 15 minutes. If irritation develops or persists, call a physician.
Inhalation (breathing) Remove person to fresh air. Call a physician if unconscious and for symptoms described above.
Comments NOTE TO PHYSICIANS: Ingestion or subsequent vomiting can result in aspiration of light hydrocarbon liquid into the lungs which can cause pneumonitis


SPILL OR RELEASE CONTROL PROCEDURES

Steps to be taken in case material is released or spilled
Eliminate all sources of ignition. Isolate and contain material, restrict entry to area. Insure adequate ventilation and absorb with appropriate inert materials. Place absorbed material into waste containers.

Waste Disposal Method
Dispose of in accordance with Federal, State and Local regulations.

ENVIRONMENTAL HAZARD (EPA-CWA, SECTION 311)
Spills of this material leading to surface waters where it will cause a sheen must be reported to the National Response Center, (800) 424-8802. This material is toxic to aquatic organisms and should be kept from sewage and drainage systems and all bodies of water.

EPA REPORTABLE QUANTITY (RQ), 40CFR302(CERCLA 104)
N/A

EPA Toxic Chemical Release Reporting, 40CFR372(SARA313)
Chemical CAS NO. % in Product
N/A N/A N/A


HANDLING AND STORAGE

Handling and Storage Precautions
Warning: Contains combustible petroleum distillates. Avoid skin contact and breathing of vapors USE ONLY IN A WELL VENTILATED AREA. Keep container closed. Keep away from flame, sparks or hot surfaces.

Other Precautions
Use entire contents. DO NOT store opened containers. Keep out of reach of children.


PERSONAL PROTECTION - EXPOSURE CONTROL

Ventilation
Provide adequate general or local ventilation to maintain concentrations below TLV/PEL limits.

Respiratory Protection
None normally required. If vapors exceed TLV/PEL values, use a NIOSH approved respirator.

Eye Protection
Safety glasses.

Protective Gloves
Chemical-resistant gloves.

Other Protective Clothing or Equipment
Eye wash station is recommended. .

Work/Hygienic Practices
Personal cleanliness is always appropriate. Frequent washing minimizes chances of inadvertent exposure.



TRANSPORTATION INFORMATION

Department of Transportation (DOT) Classification
  Flammable Liquid  Corrosive
  Flammable Solid Non Flammable Gas
  Flammable Gas Non Hazardous by DOT
Combustible Liquid  Other

DOT Proper Shipping Name
N/A (Not regulated in quantities less than 119 gallons per container)

Air (IATA) and Ocean (IMDG) Shipments
Flammable liquid, N.O.S. (Contains Aromatic Solvent), 3, UN1993, PGIII


DOCUMENTATION

Product Code No.: 66201, 66202
Previous Code No.: 66201, 66202

Issue Date: 03-09-06
Prior Date: 12-29-05

This information is, to the best of our knowledge and belief, accurate and reliable as of the date compiled. However, no representation, warranty or guarantee is made as to its accuracy, reliability or completeness. It is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use.